    Five percent do not perform daily QC; all analyzed external QC at least once per month. When QC limits exceed acceptable limits, 92% stop testing. Expired materials were used by 5%. The majority collected data for quality improvements. Eleven percent thought their organization’s POCT is acceptable. The majority of respondents believe improvements need to be made in POCT. Conclusions Analysts’ POCT practices have and are improving to contribute positively to patients’ healthcare and safety. Analysts do recognize problems and their wants/needs provide important information to improve their practices. Most participants desire more in-house and/or manufacturer training, explicit directions from manufacturers, manufacturer built-in quality and function checks, and oversight.Background There is a well-documented lack of rapid, low-cost tuberculosis (TB) drug resistance diagnostics in low-income settings across the globe. It is these areas that are plagued with a disproportionately high disease burden and in greatest need of these diagnostics. Methods In this study, we compared the performance of Light Forge, a microfluidic high-resolution melting analysis (HRMA) prototype for rapid low-cost detection of TB drug resistance with a commercial HRMA device, a predictive “nearest-neighbor” thermodynamic model, DNA sequencing, and phenotypic drug susceptibility testing (DST). The initial development and assessment of the Light Forge assay was performed with 7 phenotypically drug resistant strains of Mycobacterium tuberculosis (M.tb) that had their rpoB gene subsequently sequenced to confirm resistance to Rifampin. These isolates of M.tb were then compared against a drug-susceptible standard, H37Rv. Seven strains of M.tb were isolated from clinical specimens and individually analyzed to characterize the unique melting profile of each strain. Results Light Forge was able to detect drug-resistance linked mutations with 100% concordance to the sequencing, phenotypic DST and the “nearest neighbor” thermodynamic model. Researchers were then blinded to the resistance profile of the seven M.tb strains. In this experiment, Light Forge correctly classified 7 out of 9 strains as either drug resistant or drug susceptible. Conclusions Light Forge represents a promising prototype for a fast, low-cost diagnostic alternative for detection of drug resistant strains of TB in resource constrained settings.Background A growing body of evidence suggests that vitamin K has beneficial effects on human health, especially cardiovascular and bone health. Vitamin K1 (phylloquinone), the predominant form of vitamin K in blood, is regarded as an indicator of vitamin K status, but to our knowledge no reference intervals (RIs) have been established for vitamin K1. Methods In this population-based study, vitamin K1 was measured in serum from 3808 Caucasian individuals without diabetes from 26 to 78 years of age. The need for gender- and age-partitioned vitamin K1 reference intervals was evaluated using Lahti’s method, and exclusion criteria were defined to obtain as healthy a study group as possible. The excluded subgroups were tested for differences in mean serum vitamin K1 levels. Serum vitamin K1 levels were quantified using an in-house newly developed, validated, and highly sensitive online SPE-LC-MS/MS method with a limit of quantitation of (LOQ) 0.05 nmol/L. Results The reference interval for serum vitamin K1 was 0.22 to 3.95 nmol/L for individuals aged 26 to 44 years and 0.35 to 3.70 nmol/L for individuals aged 45 to 78. Similar age-specific reference intervals were established for vitamin K1-triglyceride ratio being 0.20 to 3.16 and 0.31 to 3.44, respectively. LY3522348 mouse No significant difference was found between genders. Serum vitamin K1 was detectable in all serum samples. Individuals with known comorbidity were found to have significantly lower serum vitamin K1 compared to those without comorbidity. Current smokers had lower serum vitamin K1 compared to nonsmokers. Conclusion Age-dependent reference intervals were established for serum vitamin K1 and vitamin K1-triglyceride ratio in a well-defined, healthy Caucasian population. Lower serum vitamin K1 levels were found in individuals with known comorbidity, suggesting an association between serum vitamin K1 and disease status. Further studies are needed to determine an optimal serum vitamin K1 level.Background Advanced glycation end products (AGEs) are formed via the nonenzymatic glycation of sugars with amino acids. Two AGEs, Nε-(1-carboxymethyl)-L-Lysine (CML) and pentosidine, have been observed to be elevated in subjects suffering from a multitude of chronic disease states, and accumulation of these compounds may be related to the pathophysiology of disease progression and aging. Methods We describe here the development and validation of a specific and reproducible LC-MS/MS method to quantify CML and pentosidine in human serum with lower limits of quantitation of 75 ng/mL and 5 ng/mL, respectively. The analyte calibration curve exhibited excellent linearity at a range of 0-10 900 ng/mL for CML and 0-800 ng/mL for pentosidine. High-low linearity of 5 serum pairs was assessed, with a mean recovery of 103% (range 94-116%) for CML, and 104% (range 97-116%) for pentosidine. Results Serum concentrations of CML and pentosidine were quantified in 30 control and 30 subjects with chronic renal insufficiency. A significant increase in both analytes was observed in renal failure compared to control subjects (2.1-fold and 8.4-fold, respectively; P less then 0.001 for both). In a separate cohort of 49 control versus 95 subjects with type 2 diabetes mellitus (T2DM), serum CML but not serum pentosidine, was significantly elevated in the T2DM patients, and CML was also correlated with glycemic control, as assessed by hemoglobin A1c (r = 0.34, P less then 0.001). Conclusions These mass spectroscopy-based assays for serum CML and pentosidine should be useful in accurately evaluating circulating levels of these key AGEs in various disease states.Background Immunosuppressant therapeutic drug monitoring (TDM) usually requires outpatient travel to hospitals or phlebotomy sites for venous blood collection; however Mitra® Microsampling Device (MSD) sampling could allow self-collection and shipping of samples to a laboratory for analysis. This study examined the feasibility of using volumetric microsampling by MSD for TDM of tacrolimus (TaC) and cyclosporin A (CsA) in transplant patients, along with their feedback on the process. Methods MSD was used to collect TaC and CsA from venous (VB) or capillary (CB) blood. The MSDs were rehydrated, extracted, and analyzed using on-line solid phase extraction coupled to tandem mass spectrometry (SPE-MS/MS). We report an abbreviated method validation of the MSD including accuracy, precision, linearity, carry-over, and stability using residual venous whole blood (VB) samples. Subsequent clinical validation compared serially collected MSD + CB against VB (200 µL) from transplant patients. Results Accuracy comparing VB vs.

Facebook Pagelike Widget

Who’s Online

Profile picture of Coley Oneal
Profile picture of Abdi Scarborough
Profile picture of Hartmann Busch
Profile picture of Sexton Werner
Profile picture of Singh Kemp
Profile picture of McCallum Clarke
Profile picture of Thyssen Villumsen
Profile picture of nawit32378
Profile picture of Crowder McClure
Profile picture of Peterson Guldager
Profile picture of Kaas Peacock