-
Potter Meldgaard posted an update 2 days, 9 hours ago
Tight regulation of the APC/C-Cdc20 ubiquitin ligase that targets cyclin B1 for degradation is important for mitotic fidelity. The spindle assembly checkpoint (SAC) inhibits Cdc20 through the mitotic checkpoint complex (MCC). In addition, phosphorylation of Cdc20 by cyclin B1-Cdk1 independently inhibits APC/C-Cdc20 activation. This creates a conundrum for how Cdc20 is activated before cyclin B1 degradation. Here, we show that the MCC component BubR1 harbors both Cdc20 inhibition and activation activities, allowing for cross-talk between the two Cdc20 inhibition pathways. Specifically, BubR1 acts as a substrate specifier for PP2A-B56 to enable efficient Cdc20 dephosphorylation in the MCC. A mutant Cdc20 mimicking the dephosphorylated state escapes a mitotic checkpoint arrest, arguing that restricting Cdc20 dephosphorylation to the MCC is important. Collectively, our work reveals how Cdc20 can be dephosphorylated in the presence of cyclin B1-Cdk1 activity without causing premature anaphase onset.Lung ultrasound is increasingly used in emergency departments, medical wards, and critical care units-adult, pediatric, and neonatal. In vitro and in vivo studies show that the number and type of artifacts visualized change with lung density. This has led to the idea of a quantitative lung ultrasound approach, opening up new prospects for use not only as a diagnostic but also as a monitoring tool. Consequently, the multiple scoring systems proposed in the last few years have different technical approaches and specific clinical indications, adaptable for more or less time-dependent patients. However, multiple scoring systems may generate confusion among physicians aiming at introducing lung ultrasound in their clinical practice. This review describes the various lung ultrasound scoring systems and aims to clarify their use in different settings, focusing on technical aspects, validation with reference techniques, and clinical applications.Keratinized mucosa (KM) is regarded as a key factor in peri-implant health. A lack of KM has been associated with discomfort, higher plaque accumulation, and mucosal inflammation. Persistent inflammation might lead to progressive peri-implant bone loss. Several approaches to manage peri-implantitis have been advocated. Despite the effectiveness shown by surgical therapeutic modalities, soft tissue conditioning seems pivotal for long-term peri-implant health and stability. Free epithelial grafts have been demonstrated to efficiently augment the band of KM. Nevertheless, morbidity, dynamic soft tissue changes, and longer healing periods are shortcomings to be considered. The purpose of this technical note is to provide an alternative therapeutic modality for the surgical management of peri-implantitis combined with simultaneous soft tissue conditioning by means of pedicle flaps. Three main clinical scenarios are provided to conceive pedicle epithelial or connective tissue flaps, combined or not with collagen matrices, as predictable approaches to augment KM in the surgical therapy of peri-implantitis.This randomized split-mouth preliminary clinical trial aimed to evaluate periodontal parameters and gingival blood flowmetry, comparing sites that received subepithelial connective tissue graft from the palate after deepithelialization (DE) or obtained with parallel incision (PI). Periodontal parameters were evaluated at baseline and 6 months postoperative. Gingival blood flows were analyzed by laser Doppler flowmetry (LDF) at baseline and 2, 7, and 14 days postoperative. Statistical and LDF analyses were performed with R version 3.5.1 and MATLAB software, and clinical parameters through ANOVA and Wilcoxon signed-rank tests. LDF showed superior decrease in power spectral density (PSD) for DE after 2 days. After 7 days, PSD returned to initial values only for PI, and DE had not returned to the initial values by day 14. Despite major initial revascularization challenges for DE sites, both grafts promoted satisfactory root coverage in the treatment of multiple gingival recessions.This study aimed to evaluate facial peri-implant tissue dimensions for implants connected to either convex or concave final abutments. Patients (n = 28) were randomly allocated to receive a single implant with an abutment of either convex (Group CX) or concave (Group CV) emergence shape. Twelve months after implant placement, CBCT scans were taken and reference points were identified first visible bone-to-implant contact, implant shoulder (IS), bone crest (BC), and marginal mucosal level (MML). Mucosal thickness was evaluated at the level of IS (MT1), above the level of BC (MT2), and at the mid-distance of BC-MML (MT3). selleck compound The mean total vertical peri-implant mucosa height was 3.26 ± 0.77 mm for Group CX and 3.70 ± 0.99 mm for Group CV (P = .23). The mean vertical peri-implant mucosa height below the bone crest was 0.62 ± 0.57 mm for Group CX and 1.26 ± 0.95 mm for Group CV (P = .04). Group CV had greater mean MT2 (4.09 ± 0.72 mm vs 3.36 ± 0.81 mm; P = .02) and MT3 (2.81 ± 0.66 mm vs 2.03 ± 0.60 mm; P = .005) compared to Group CX. Abutment macrodesign may have an effect on vertical and horizontal peri-implant tissue dimensions.The efficacy of the socket preservation procedure using deproteinized bovine bone mineral, bioabsorbable collagen membrane, and collagen sponge on molar extraction sites with severe periodontitis was assessed at 6 postoperative months, before implant placement. Results revealed excellent soft tissue healing without loss of keratinized tissue and no statistically significant differences in socket marginal bone changes in 20 molar extraction sockets. High levels of primary implant stability were recorded. Socket preservation using a minimally invasive surgical technique provides good soft and hard tissue healing as well as anticipated stability of implant placement at sites of extracted molars with severe periodontitis.This study aimed to rehabilitate shortened maxillary dental arch with splinted crowns by connecting ultra-short implants with longer ones. In the posterior maxilla of 11 patients, one 10-mm (n = 11) and one or two ultra-short 4-mm (n = 17) dental implants were inserted. The insertion torque was lower than 20 Ncm in 55% of the 10-mm implants and in 94% of the 4-mm implants (P > .05). Median (range) implant stability quotients at the time of insertion and after 6 months were 61 (14 to 72) and 68 (51 to 79), respectively, for 4-mm implants, and 66 (52 to 78) and 78 (60 to 83), respectively, for 10-mm implants (P .05). Splinted crowns combining 4- and 10-mm implants may contribute to a better force distribution in the treatment with ultra-short implant-supported prosthesis in the posterior maxilla.