Photodynamic therapy (PDT) is a licensed and established procedure for the treatment of actinic keratosis, basal cell carcinoma, and Bowen’s disease, but there are several new and clinically relevant developments and trends. These concern on the one hand the main components of PDT, which are the photosensitizer and the light source. Furthermore, modifications and therapy combinations have been developed that lead to an improved therapeutic efficacy. An important aspect of field-directed PDT is also skin cancer prevention. Finally, PDT has been used successfully for nonlicensed indications including inflammatory diseases and skin rejuvenation. This article focuses on these new developments and on recent guideline recommendations.The aim of this study is to investigate the gene expression module of tumor-infiltrating CD4+T cells and its potential roles in modulating immune cell functions in triple-negative breast cancer. Differentially expressed genes were identified by comparison of the expression profile in CD4+T cells isolated from tumor tissues and peripheral blood of TNBC patients respectively. The differential expression analysis was conducted using R, and then the functional and pathway enrichment of the DEGs were analyzed using GSEA, followed by integrated regulatory network construction and genetic analysis of tumor-infiltrating immune cells based on a scientific deconvolution algorithm. As a result, abundant Treg and exhausted lymphocytes were detected, accompanied by largely decreased of effector/memory and cytotoxic T cells. Immune-related gene correlation analysis showed that the extent of follicular helper T cells gene expression signatures were inversely associated with those of CD4+ naive T cells and CD4+ memory resting T cells, but positively correlated with that of CD4+ memory activated T cells. In addition, we found five core genes including IFNG, CTLA4, FAS, CXCR6, and JUN were significantly over expressed in CD4+ TILs which may contribute to exhaustion of lymphocytes and participate in biological processes associated with regulation of chemotaxis. Study provides a comprehensive understanding of the roles of DEGs associated with the chemotactic and exhausted immunophenotypes of CD4+ TILs that are a valuable resource from which future investigation may be carried out to better understand the mechanisms that promote TNBC progression.
High temperatures at workplaces lead to health-related risks and premature exhaustion. The coronavirus disease 2019 (COVID-19) pandemic requires many health professionals to perform under unfavorable conditions. Personal protective equipment (PPE) causes thermal stress and negatively affects performance.
This pilot project investigated the effects of PPE and additional cooling wear on physiological parameters and concentration of six healthy staff members of the Plastic Surgery Department of the Medical University of Graz, Austria during simulated patient care. In this study two 1‑hour cycles with patient care-related tasks with PPE and PPE + cooling-wear, respectively, were conducted. Athird cycle with scrubs exclusively served as baseline/negative control. The assessment occurred immediately pre-cycles and post-cycles.
Pre-cycle assessments showed no significant differences between the cycles. After PPE cycle, increased physical stress levels and decrements in concentration capacity were observed. Physiological parameters were significantly less affected in the cooling cycle, while concentration capacity slightly increased.
COVID-19 PPE causes considerable thermal stress, ultimately affecting human performance. As opportunity to withstand thermal stress, and improve patients’ and professionals’ safety, cooling-wear can be considered relevant. Medical personnel performing in exceptional situations may particularly benefit from further development and investigation of cooling strategies.
COVID-19 PPE causes considerable thermal stress, ultimately affecting human performance. As opportunity to withstand thermal stress, and improve patients’ and professionals’ safety, cooling-wear can be considered relevant. Medical personnel performing in exceptional situations may particularly benefit from further development and investigation of cooling strategies.
The present study attempted to demonstrate how the configuration of hydrogel-coated coils is influenced by different temperature exposures. Thirty detachable hydrogel-coated coils were evaluated in an in vitro water immersion test under five different temperature ranges (22.6 °C, 37 °C, 40-50 °C, 50-60 °C, and 60-70 °C). The configuration changes were classified (configuration I, configuration II, and configuration III) according to the curling that occurred during 30 min of immersion. Configuration stability of five Hydrogel-coated coils was also evaluated in a two-step temperature immersion test.
All hydrogel-coated coils showed some configuration changes during water immersion. However, a logarithmic transformation of the time and temperature data showed a significant (p < 0.05) negative linear correlation between time and temperature for all coil configurations (configuration I R = 0.97, configuration II R = 0.98, configuration III R = 0.97). The time needed to reach configuration III (complete coiling) was 160.4 ± 41.9 s at 37.5 °C (range 100-205 s), 45.7 ± 22.2 s at 47.5 °C (range 23-70 s), 20.2 ± 7.2 s at 57.5 °C (range 14-32 s), and 10.3 ± 2.4 s at 67.5 °C (range 7-13 s).
Temperatures above 55 °C induced immediate configurational changes in the hydro-coated coils, achieving complete curling within less than 30 s. Temperatures near 36 °C (normal body temperature) require more time to reach optimal coil curling (configuration III). click here The optimization of HydroCoil preparation can reduce interventional procedural time and improve clinical results.
Temperatures above 55 °C induced immediate configurational changes in the hydro-coated coils, achieving complete curling within less than 30 s. Temperatures near 36 °C (normal body temperature) require more time to reach optimal coil curling (configuration III). The optimization of HydroCoil preparation can reduce interventional procedural time and improve clinical results.